ISSN 0862-5468 (Print), ISSN 1804-5847 (online) 

Ceramics-Silikáty 48, (1) 34 - 39 (2004)


X-RAY QUANTITATIVE PHASE ANALYSIS OF RESIDUEM OF THE REFERENCE PORTLAND CLINKERS
 
Pritula Ondrej 1, Smrčok Ľubomír 1, Ivan Jozef 2, Iždinský Karol 2
 
1 Institute of Inorganic Chemistry, Slovak Academy of Sciences Dúbravská cesta 9, 845 36 Bratislava, Slovak Republic
2 Institute of materials and machine mechanics, Račianska 75, 831 02, Bratislava, Slovak Republic

Keywords: Quantitative phase analysis, Rietveld refinement, Portland clinker
 

Residues obtained from the chemical treatment of three Reference Portland clinkers (8486, 8487 and 8488) were analyzed by SEM and X-ray Rietveld quantitative phase analysis. It was found that the chemical treatment was not fully selective. Calculated weight fractions were compared to the weight fraction intervals obtained from a previous analysis of complete clinkers. It was found that in general the refinements based on the diffraction patterns of residues performed better than those based on the patterns of complete clinkers, even though the calculated weight fraction ratios lie mostly within the intervals reported previously. The most important conclusion for daily practice is that if one just wishes to achieve more reliable results in X-ray quantitative phase analysis the improvement is not worth the time and work invested into the chemical treatment of the clinkers.


PDF (0.1 MB)
 
Licence Creative Commons © 2015 - 2024
Institute of Rock Structure and Mechanics of the CAS & University of Chemistry and Technology, Prague
Webmaster | Journal Contact