ISSN 0862-5468 (Print), ISSN 1804-5847 (online) 

Ceramics-Silikáty 52, (3) 130 - 138 (2008)


ADHESION OF THE BIOACTIVE LAYER ON TITANIUM ALLOY SUBSTRATE BY TAPE-TEST
 
Horkavcová Diana 1, Plešingerová Beatrice 2, Helebrant Aleš 1, Vojtko Marek 3, Procházka Václav 1
 
1 Department of Glass and Ceramics, Institute of Chemical Technology, Prague, Technická 5, 166 28 Prague Czech Republic
2 Department of Ceramics, Faculty of Metallurgy, Technical University of Košice, Letná 9/A, 040 02 Košice, Slovak Republic
3 Department of Material Sciences, Faculty of Metallurgy, Technical University of Košice, Letná 9/A, 040 02 Košice, Slovak Republic

Keywords: Adhesion, Tape-test, Ti6Al4V, Surface treatment, Precalcification
 

The aim of this work was to check whether the ASTM D 3359 is a suitable method for adhesion measurement of the layers formed on Ti6Al4V surfaces by a) alkali treatment in 10 mol/l NaOH, b) precalcification in SCS (supersaturated calcification solution) and c) in vitro tests in SBF (simulated body fluid). Tape-test is suitable for evaluation of adhesion of coatings after chemical treatment and after short-time precalcification. Adhesion of the coatings is excellent, classified into category 5. The test is not suitable for coatings precalcified for the long time when the big spherical crystals are formed. The cracking of the coatings during drying of samples inhibits obtaining reliable results of adhesion of HA-coatings to substrate after in vitro tests.


PDF (4.6 MB)
 
Licence Creative Commons © 2015 - 2024
Institute of Rock Structure and Mechanics of the CAS & University of Chemistry and Technology, Prague
Webmaster | Journal Contact