Ceramics-Silikáty 54, (1) 1 - 7 (2010) |
|
PROCESSING AND CHARACTERISATION OF HIGH-VELOCITY SUSPENSION FLAME SPRAYED (HVSFS) BIOACTIVE GLASS COATINGS |
Bolelli Giovanni 1, Cannillo Valeria 1, Gadow Rainer 2,
Killinger Andreas 2,
Lusvarghi Luca 1,
Rauch Johannes 2 |
1 Department of Materials and Environmental Engineering, University of Modena and Reggio Emilia,
Via Vignolese 905, I-41100 Modena, Italy
2 Institute for Manufacturing Technologies of Ceramic Components and Composites (IMTCCC), University of Stuttgart,
Allmandring 7b, D-70569 Stuttgart, Germany
|
Keywords: High-Velocity Suspension Flame Spraying (HVSFS), Bioactive glass coatings, Suspension rheology, Scanning electron microscopy (SEM), Micro-Raman spectroscopy |
The High-Velocity Suspension Flame Spraying (HVSFS) technique was employed in order to deposit bioactive glass coatings
onto titanium substrates. Two different glass compositions were examined: the classical 45S5 Bioglass and a newly-developed
SiO₂–CaO–K₂O–P₂O₅ glass, labelled as “Bio-K”. Suitable raw materials were melted in a furnace and fritted by casting
into water. The frit was dry-milled in a porcelain jar and subsequently attrition-milled in isopropanol. The resulting micronsized
powders were dispersed in a water+isopropanol mixture, in order to prepare suitable suspensions for the HVSFS
process. The deposition parameters were varied; however, all coatings were obtained by performing three consecutive torch
cycles in front of the substrate. The thickness and porosity of the coatings were significantly affected by the chosen set of
deposition parameters; however, in all cases, the layer produced during the third torch cycle was thicker and denser than
the one produced during the first cycle. As the system temperature increases during the spraying process, the particles
sprayed during the last torch cycle remain at T > Tg while they spread, so that interlamellar viscous flow sintering takes
place, favouring the formation of such denser microstructure. Both coatings are entirely glassy; however, micro-Raman
spectroscopy reveals that, whereas the 45S5 coating is structurally identical to the corresponding bulk glass, the “Bio-K”
coating is somewhat different from the bulk one |
PDF (2.5 MB) |
|