Ceramics-Silikáty 63, (3) 287 - 290 (2019) |
|
LEACHING KINETICS OF IZOMER TT GLASS FIBROUS INSULATION |
Vokelová Jana 1, Michálková Jaroslava 1, Chromčíková Mária 3, 2, Hruška Branislav 4, Liška Marek 3
, 2 |
1 FunGlass, A. Dubcek University of Trenčín, Študentská 2, SK-911 50 Trenčín, Slovakia
2 VILA, Joined Glass Centre of the IIC SAS, TnUAD, FChPT STU, Študentská 2,
SK-911 50 Trenčín, Slovakia
3 VILA, FunGlass, A. Dubcek University of Trenčín, Študentská 2, SK-911 50 Trenčín, Slovakia
4 Central Laboratories, FunGlass, Alexander Dubček University of Trenčín, Študentská 2,
SK-911 50 Trenčín, Slovakia
|
Keywords: Glass corrosion, LOCA, Glass fibrous insulation, Leaching kinetics |
Chemical durability of glass with the composition of glass fibrous insulation IZOMER TT commonly used in nuclear power plants reactor containment was tested by static leaching tests at 70°C, 80°C, and 90°C. Distilled water and borate coolant solution were used as corrosive media. The semiempirical kinetic model based on the Aagaard Helgeson kinetic equation was proposed and qualified. Proposed model enables prediction of glass dissolution kinetics for various time-temperature schedules proposed for different Loss of Coolant Accident scenarios. |
PDF (0.8 MB) |
doi: 10.13168/cs.2019.0022 |
|